File name: Honeywell Zone Valve Wiring Pdf
Rating: 4.8 / 5 (2484 votes)
Downloads: 43215
========================
👉Honeywell Zone Valve Wiring Pdf
========================
The VE and F also control supply water for baseboard radiators and convectors Valve ball shall be nickel-plated brass. V MOTORISED ZONE VALVEC—WIRING Below are the wiring connections. When the manual opener is set to AUTO and the actuator is energized, port A of the valve opens. The V and V provide two-position, diverting control of supply water. The valves are designed for use with fan coil and other units requiring quiet, compact water valves. If replacing a Taco, Dole, Flair or White Rodgerswire valve with awire VE or F, see Figthrough Check that the pressure rating of the new valve is Function. VCposition normally closed hydronic valves are used in domestic and small commercial applications to control the flow of hot water. When the actuator is de-energized, a spring-return mechanism The V and V provide two-position, straight-through control of supply water. VCposition normally closed hydronic valves are used in domestic and small commercial applications to control the flow of hot water. Valve stem shall be stainless steel. They consist of an actuator and a valve. (See Mounting Section.)Make wiring connections to valve. Connections to the individual valves are shown in FigSee Figthroughfor typical hookups. Valve stem assembly shall be of a pack-less design The valves are The VN series zone valves and actuators are space-saving compactorway ball valves, factory assembled and tested with electronic rotary fail-in-place or electronic-fail TO INSTALL A COMPLETE VALVE (V)Disconnect power supply before connecting wiring to prevent electrical shock or equipment damageInstall valve into pipe on the return side of the coil. Ensure the fixed wiring connection to the mains supply is via a fuse rated Function. If replacing a The V and V provide two-position, straight-through control of supply water. (Refer to Wiring section for proper instructions.)Inspect the valve installation to All wiring must comply with local codes and ordinances. They consist of an All wiring must comply with local codes and ordinances. The V and V provide two-position, diverting control of supply water. Connections to the individual valves are shown in FigSee Figthroughfor typical hookups. Differential close-off pressure shall be at leastpsid forway andway valves with leakage rate of % of Cv. Threaded valves bodies shall have nominal pressure rating of psig (kPa).